    Panoramic Elevator

    • Panoramic elevators provide passenger with a wide view and upgrade building value, and are applicable to hotel, shopping center etc. LGS panoramic elevators are designed by Korean professional elevator designer and engineered by highly qualified Korean engineers. It ensures to provide customers with various panoramic options, attractive aesthetic decorations and excellent quality products.

    • PANORAMIC ELEVATOR CAR DESIGN 1 SIDE VIEW

    • PANORAMIC ELEVATOR CAR DESIGN 2 SIDE VIEW

    • PANORAMIC ELEVATOR CAR DESIGN 3 SIDE VIEW

    • PANORAMIC ELEVATOR CAR DESIGN ROUND VIEW

    • PLANNING GUIDE Panoramic - 1 Slide / 2 Side View

    • PLANNING GUIDE Panoramic - Panoramic - 3 Side View

    • PLANNING GUIDE Panoramic - Panoramic - 1 Side / 2 Side View

    • PLANNING GUIDE Panoramic - Panoramic - Round View

    1 SIDE VIEW (SPEED : 1.0~1.75m/s) [unit : mm]
    Speed Person Load OP Car Insize Hoistway Reactions M/C Room Overhead
    PIT
    Single(1unit) Duplex(2units) R1(Car) R2(C.wt)
    [m/sec] [kg] [OP] CW CD HW HD HW HD [kg]

    [kg]

    1.0
    1.5
    1.75
    6 450 800 1400 850 2200 1450 4550 1450 4000 3100 2400 4500 / 4600 / 4700 2000 / 2300
    8 550 800 1400 1050 2200 1600 4550 1600 4300 3400 2400 4500 / 4600 / 4700 2000 / 2300
    9 600 800 1400 1100 2200 1700 4550 1700 4500 3500 2400 4500 / 4600 / 4700 2000 / 2300
    9 630 800 1400 1150 2200 1800 4550 1800 4600 3600 2400 4500 / 4600 / 4700 2000 / 2300
    10 700 800 1400 1250 2200 1850 4550 1850 4700 3700 2400 4500 / 4600 / 4700 2000 / 2300
    11 800 800 1400 1350 2200 1950 4550 1950 5000 4000 2400 4500 / 4600 / 4700 2000 / 2300
    13 900 900 1400 1350 2400 1950 4950 1950 6300 4400 2400 4500 / 4600 / 4700 2000 / 2300
    15 1000 900 1600 1500 2400 2100 4950 2100 6700 4700 2400 4500 / 4600 / 4700 2000 / 2300
    17 1150 1000 1800 1500 2800 2100 5750 2100 10100 6000 2400 4500 / 4600 / 4700 2000 / 2300
    20 1350 1000 1800 1700 2800 2300 5750 2300 10700 6500 2400 4500 / 4600 / 4700 2000 / 2300
    24 1600 1100 2000 1750 3000 2350 6150 2350 12100 6700 2400 4500 / 4600 / 4700 2000 / 2300
    30 2000 1200 2000 2000 3000 2600 6150 2600 12900 7100 2400 4500 / 4600 / 4700 2000 / 2300

    1 SIDE VIEW (SPEED : 1.0~1.75m/s)

    1 SIDE VIEW (SPEED : 2.0~2.5m/s) [unit : mm]
    Speed Person Load OP Car Insize Hoistway Reactions M/C Room Overhead
    PIT
    Single(1unit) Duplex(2units) R1(Car) R2(C.wt)
    [m/sec] [kg] [OP] CW CD HW HD HW HD [kg]

    [kg]

    2.0
    2.5
    13 900 900 1600 1350 2400 2000 4950 2000 6300 4400 2500 5000 / 5500 2100 / 2400
    15 1000 900 1600 1500 2400 2150 4950 2150 6700 4700 2500 5000 / 5500 2100 / 2400
    17 1150 1000 1800 1500 2800 2150 5750 2150 10100 6000 2500 5000 / 5500 2100 / 2400
    20 1350 1000 1800 1700 2800 2350 5750 2350 10700 6500 2500 5000 / 5500 2100 / 2400
    24 1600 1100 2000 1750 3000 2400 6150 2400 12100 6700 2500 5000 / 5500 2100 / 2400
    30 2000 1100 2000 2000 3000 2650 6150 2650 12900 7100 2500 5000 / 5500 2100 / 2400

    1 SIDE VIEW (SPEED : 2.0~2.5m/s)

    2 SIDE VIEW (SPEED : 1.0~1.75m/s) [unit : mm]
    Speed Person Load OP Car Insize Hoistway Reactions M/C Room Overhead
    PIT
    Single(1unit) Duplex(2units) R1(Car) R2(C.wt)
    [m/sec] [kg] [OP] CW CD HW HD HW HD [kg]

    [kg]

    1.0
    1.5
    1.75
    8 550 800 1400 1050 2250 1650 4650 1650 4700 3800 2400 4500 / 4600 / 4700 2000 / 2300
    9 600 800 1400 1100 2250 1700 4650 1700 4900 3900 2400 4500 / 4600 / 4700 2000 / 2300
    9 630 800 1400 1150 2250 1800 4650 1800 5000 4000 2400 4500 / 4600 / 4700 2000 / 2300
    10 700 800 1400 1250 2250 1850 4650 1850 5100 4100 2400 4500 / 4600 / 4700 2000 / 2300
    11 800 800 1400 1350 2250 1950 4650 1950 5400 4400 2400 4500 / 4600 / 4700 2000 / 2300
    13 900 900 1600 1350 2500 1950 5150 1950 6700 4800 2400 4500 / 4600 / 4700 2000 / 2300
    15 1000 900 1600 1500 2500 2100 5150 2100 7100 5100 2400 4500 / 4600 / 4700 2000 / 2300
    17 1150 1000 1800 1500 2850 2100 5850 2100 10400 6400 2400 4500 / 4600 / 4700 2000 / 2300
    20 1350 1000 1800 1700 2850 2300 5850 2300 11100 6900 2400 4500 / 4600 / 4700 2000 / 2300
    24 1600 1100 2000 1750 3050 2350 6250 2350 12500 7100 2400 4500 / 4600 / 4700 2000 / 2300
    30 2000 1200 2000 2000 3050 2600 6250 2600 13300 7500 2400 4500 / 4600 / 4700 2000 / 2300

    2 SIDE VIEW (SPEED : 1.0~1.75m/s)

    2 SIDE VIEW (SPEED : 2.0~2.5m/s) [unit : mm]
    Speed Person Load OP Car Insize Hoistway Reactions M/C Room Overhead
    PIT
    Single(1unit) Duplex(2units) R1(Car) R2(C.wt)
    [m/sec] [kg] [OP] CW CD HW HD HW HD [kg]

    [kg]

    2.0
    2.5
    13 900 900 1600 1350 2500 1950 5150 1950 6700 4800 2500 5000 / 5500 2100 / 2400
    15 1000 900 1600 1500 2500 2100 5150 2100 7100 5100 2500 5000 / 5500 2100 / 2400
    17 1150 1000 1800 1500 2850 2100 5850 2100 10400 6400 2500 5000 / 5500 2100 / 2400
    20 1350 1000 1800 1700 2850 2300 5850 2300 11100 6900 2500 5000 / 5500 2100 / 2400
    24 1600 1100 2000 1750 3050 2350 6250 2350 12500 7100 2500 5000 / 5500 2100 / 2400
    30 2000 1100 2000 2000 3050 2600 6250 2600 13300 7500 2500 5000 / 5500 2100 / 2400

    Note. 1. Above dimensions in table shall be under the following conditions
                 1) Door opening : 2panel Center opening (2P-CO), 2) No. of Door in Car : 1Car 1Door
             2. OH, PIT dimensions shall be under the following condition
                 Entrance Height : 2100mm, Cab Height : Manufacturer's standard

    2 SIDE VIEW (SPEED : 2.0~2.5m/s)

    3 SIDE VIEW (SPEED : 1.0~1.75m/s) [unit : mm]
    Speed Person Load OP Car Insize Hoistway Reactions M/C Room Overhead
    PIT
    Single(1unit) Duplex(2units) R1(Car) R2(C.wt)
    [m/sec] [kg] [OP] CW CD HW HD HW HD [kg]

    [kg]

    1.0
    1.5
    1.75
    10 700 800 1400 1250 2350 1900 4850 1900 5800 3900 2400 4500 / 4600 / 4700 2000 / 2300
    11 800 800 1400 1350 2350 2000 4850 2000 6700 4500 2400 4500 / 4600 / 4700 2000 / 2300
    13 900 900 1600 1350 2500 2000 5150 2000 7300 4700 2400 4500 / 4600 / 4700 2000 / 2300
    15 1000 900 1600 1500 2500 2150 5150 2150 7600 5000 2400 4500 / 4600 / 4700 2000 / 2300
    17 1150 1000 1800 1500 2850 2150 5850 2150 10200 6400 2400 4500 / 4600 / 4700 2000 / 2300
    20 1350 1000 1800 1700 2850 2350 5850 2350 11100 6700 2400 4500 / 4600 / 4700 2000 / 2300
    24 1600 1100 2000 1750 3150 2400 6450 2400 12200 7100 2400 4500 / 4600 / 4700 2000 / 2300
    30 2000 1200 2000 2000 3150 2650 6450 2650 13000 7500 2400 4500 / 4600 / 4700 2000 / 2300

    3 SIDE VIEW (SPEED : 1.0~1.75m/s)

    3 SIDE VIEW (SPEED : 2.0~2.5m/s) [unit : mm]
    Speed Person Load OP Car Insize Hoistway Reactions M/C Room Overhead
    PIT
    Single(1unit) Duplex(2units) R1(Car) R2(C.wt)
    [m/sec] [kg] [OP] CW CD HW HD HW HD [kg]

    [kg]

    2.0
    2.5
    13 900 900 1600 1350 2500 2000 5150 2000 7300 4700 2500 5000 / 5500 2100 / 2400
    15 1000 900 1600 1500 2500 2150 5150 2150 7600 5000 2500 5000 / 5500 2100 / 2400
    17 1150 1000 1800 1500 2850 2150 5850 2150 10200 6400 2500 5000 / 5500 2100 / 2400
    20 1350 1000 1800 1700 2850 2350 5850 2350 11100 6700 2500 5000 / 5500 2100 / 2400
    24 1600 1100 2000 1750 3150 2400 6450 2400 12200 7100 2500 5000 / 5500 2100 / 2400
    30 2000 1200 2000 2000 3150 2650 6450 2650 13000 7500 2500 5000 / 5500 2100 / 2400

    3 SIDE VIEW (SPEED : 2.0~2.5m/s)

    Round VIEW (SPEED : 1.0~1.75m/s) [unit : mm]
    Speed Person Load OP Car Insize Hoistway Reactions M/C Room Overhead
    PIT
    Single(1unit) Duplex(2units) R1(Car) R2(C.wt)
    [m/sec] [kg] [OP] CW CD HW HD HW HD [kg]

    [kg]

    2.0
    2.5
    11 800 800 1300 1600 2250 2200 4650 2200 6100 4400 2400 4500 / 4600 / 4700 2000 / 2300
    13 900 900 1300 1800 2250 2400 1650 2400 7100 5250 2400 4500 / 4600 / 4700 2000 / 2300
    15 1000 900 1400 1860 2400 2450 4950 2450 7600 5300 2400 4500 / 4600 / 4700 2000 / 2300
    17 1150 1000 1500 1960 2500 2550 5150 2550 10200 6800 2400 4500 / 4600 / 4700 2000 / 2300
    20 1350 1000 1600 2080 2650 2700 5450 2700 11250 6900 2400 4500 / 4600 / 4700 2000 / 2300
    24 1600 1100 1700 2240 2850 2850 5850 2850 12500 7000 2400 4500 / 4600 / 4700 2000 / 2300

    Round VIEW (SPEED : 1.0~1.75m/s)

    Round VIEW (SPEED : 2.0~2.5m/s) [unit : mm]
    Speed Person Load OP Car Insize Hoistway Reactions M/C Room Overhead
    PIT
    Single(1unit) Duplex(2units) R1(Car) R2(C.wt)
    [m/sec] [kg] [OP] CW CD HW HD HW HD [kg]

    [kg]

    2.0
    2.5
    13 900 900 1300 1800 2400 2400 4950 2400 7100 5200 2500 5000 / 5500 2100 / 2400
    15 1000 900 1400 1860 2500 2450 5150 2450 7600 5300 2500 5000 / 5500 2100 / 2400
    17 1150 1000 1500 1960 2650 2550 5450 2550 10200 6800 2500 5000 / 5500 2100 / 2400
    20 1350 1000 1600 2080 2750 2700 5650 2700 1250 6900 2500 5000 / 5500 2100 / 2400
    24 1600 1100 1700 2240 2950 2850 6050 2850 2500 7000 2500 5000 / 5500 2100 / 2400

    Note. 1. Above dimensions in table shall be under the following conditions
                 1) Door opening : 2panel Center opening (2P-CO), 2) No. of Door in Car : 1Car 1Door
             2. OH, PIT dimensions shall be under the following condition
                 Entrance Height : 2100mm, Cab Height : Manufacturer's standard

    Round VIEW (SPEED : 2.0~2.5m/s)

    Technical Features

    Feature Description Remark
    Full collective selective In automatic running or attendant state, this function enables the elevator to respond both car calls and hall calls.
    Passengers at any service floor can call the elevator by pressing the up call button and down call button.
    Anti-nuisance function The system automatically judges the number of passengers in the car and compares it with the number of registered car calls.
    If there are excessive car calls, the system determines that it is nuisance and cancels all car calls. In this case, passengers need to register correct car calls again.
    Car Call Cancellation Passengers can press the button consecutively twice to cancel wrong calls.
    Turn Off of Car Light
    and Fan
    If there is no running command within the set time, the system automatically cuts off the power supply to the lamp and fan in the car.
    Full-load direct runnung When the car is full-loaded in automatic running state, the elevator does not respond to hall calls from the passing floors. These halls calls, however,
    can still be registered, and will be executed at next time of running (in the case of single elevator) or by another elevator
    (in the case of parallel/group control).
    Overload protection When the car load exceeds the rated elevator load, the elevator alarms and stops running.
    Button stuck check The system can automatically identify whether a hall call button is stuck and cancel the stuck call,
    preventing the condition that the elevator cannot close and run due to stuck hall calls.
    Repeat door close If the door lock is not applied after the elevator performs door close for a certain time, the elevator automatically opens the door and then closes the
    door again.
    Automatic door open upon door
    lock abnormality
    If the system detects that the door lock circuit is abnormal during door open/close, the elevator automatically opens and closes the door again,
    and reports a fault after the set door open/close times is reached.
    Door open time setting The system automatically determines different door open time for door open for call, command, protection,
    or delay according to the set door open holding time.
    Arrival gong disabled at night Within the set time period, the arrival gong is disabled.
    Landing at another floor If the door open time exceeds the door open protection time but the door open limit signal is still inactive, the elevator closes the door and then automatically runs to the next landing floor.
    Voice Announcement The elevator automatically announces information such as the running direction and next arriving floor
    during running.
    Forced door close When the door fails to close within the set time due to the action of the light curtain or safety edge, the elevator enters the forced door close state,
    closes the door slowly, and gives a prompt tone.
    Group control The system supports parallel control of two elevators / group control of more than three elevators
    Micro Leveling After landing at a floor, the elevator may move upward or downward due to the load change and the car door is not aligned with the ground,
    which is inconvenient for in and out of passengers and goods. In this case, the system allows the elevator to run to the leveling position in the door
    open state at the leveling speed.
    Light curtain signal judgment If the door is blocked by stuff during door close, the light curtain acts and the elevator opens the door. This function is invalid in fire emergency state.
    Power failure emergency
    evacuation
    For the elevator configured with standby power supply, the system uses the standby power supply (ARD System) to implement low-speed self-rescue
    in the case of power failure.
    Residential monitoring The control system can be connected to the terminal in the monitoring room. By using the NEMS software,
    you can view the floor position, running direction, and fault state of the elevator.
    Parking Operation In order for park the elevator, if the parking key is on position the car stop at the specified floor after finish servicing of all of registered call.
    After the car stops at the specified floor, the car light and fan are off automatically and every buttons both on the car operating panel and
    hall button box are no more available.
    Fire return Operation In case of fire every cars should be returned to the specified floor in order to evacuate passengers safety.
    Fireman Operation In case of fire, a fireman can use the elevator which is stopped at the specified floor in order to support fireman for fire-fighting.

    Technical Features

    Works Others

    Work by Others

    The works below are not included in the elevator installation work and should be carried out by building contractors in accordance with our drawing, relevant international or codes and regulations.

    Hoistway

    -A property framed and enclosed hoistway, including any ventilation as required by the governing code or authority.

    -A dry pit constructed to the elevator manufacture's specifications to reinforce or sustain any vertical forces on the guide rails impacted loads from the car and counterweight buffers.

    -A metal still angle or concrete haunch across the full width of the hoistway at each elevator landing.

    -Provision of steel bars to fix jamb around the entrance of each floor.

    -All cutting, including cutouts to accommodate hall signal fixtures, patching, painting of wall, floors, or partitions, together with finish painting of entrance doors and frame, if required.

    -Provision of entrance or ladder for pit access.

    -Supply and installation of fascia plate

    -Installation of emergency exits and electric wiring in blind sections of hoistway where required.

    -the tolerance of emergency exits and electric wiring in build sections of hoistway where required.

    -The tolerance of perpendicular line over the whole hoistway height must not exceed ±30mm.

    -A waterproof outlet and light fixture in the elevator pit area with the light switch being located adjacent to the access door ladder.

    -Suitable light fixture and convenience outlet in the pit with a light switch adjacent to the access door or ladder. The receptacles shall have protection for ground.

    Machine Room

    -Provision of wiring between controller and building management system.

    -A construction hoisting beam or hook, if require, with the correct location and size as determined by elevator contractor for each hoistway.

    -Noise insulation should be installed between machine room and adjacent residential area.

    -A suitable machine room with legal access, ventilation and concrete floor . The temperature in the machine room should be maintained between 5℃ and 40℃ Relative humidity should not exceed 90%(monthly) and 95%(daily) non-condensing.
    Ventilation fan or air conditioner should be provided as per heat dissipation by the elevator contractor.

    -The size of entrance shall be min. 1000mm(w) X 2000mm(H).

    -Installation of lead-in wire and earth wire between building main power board and room incoming distribution board. However, machine room lighting source supply shall be install separately.

    -Provision of suitable light fixture and convenience outlets in the machine room.

    Miscellaneous

    -Wiring and piping between each machine room and monitoring system.

    -Machine room and hoistway shall be free or harmful gas.

    -All electric power for lighting, tools, welding, etc during installation.

    -All single phase receptacles installed in machine room, pit and machinery spaces shall ground fault circuit interrupter

    Protection.

    -Fire detector for emergency operation.

    - A secured area for storage of elevator equipment and materials during installation.